40W Triple Output Switching Power Supply

.LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT
.105ºC  OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
MODEL
SPECIFICATION
SM-T40A SM-T40B SM-T40C
CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC OUTPUT VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V
OUTPUT V. TOLERANCE ±2% ±6% ±8% ±2% ±6% ±8% ±2% ±6% ±6%
OUTPUT RATED CURRENT 3A 2A 0.5A 3A 2A 0.5A 3A 1.5A 0.5A
OUTPUT CURRENT RANGE 0.6-5A 0.2-3A 0.1-1A 0.6-5A 0.2-3A 0.1-1A 0.6-5A 0.2-2A 0.1-1A
RIPPLE & NOISE 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
LINE REGULATION ±0.5% ±1% ±1% ±0.5% ±1% ±1% ±0.5% ±1% ±1%
LOAD REGULATION ±0.5% ±4% ±6% ±0.5% ±4% ±6% ±0.5% ±4% ±4%
RATED OUTPUT POWER 41.5W 45W 45W
EFFICIENCY 72% / 115VAC 72% / 115VAC 72% / 115VAC
DC VOLTAGE ADJ. CH1:+10,-5% CH1:+10,-5% CH1:+10,-5%
INPUT VOLTAGE RANGE 85~264VAC   47~63Hz  ;  120~370VDC
AC CURRENT 1.2A/115V  0.7A/230V
INRUSH CURRENT COLD START  20A/115V   40A/230V
LEAKAGE CURRENT <3.5mA/240VAC
OVERLOAD PROTECTION 105%~150%/115VAC  TYPE:PULSING HICCUP SHUTDOWN  RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION CH1:5.75~6.75V
TEMP. COEFFICIENT ±0.03% / ºC  (0~50ºC) ON +5V OUTPUT
SETUP,RISE,HOLD UP TIME 1.6s, 50ms, 16ms / 115VAC  800ms, 50ms, 60ms / 230VAC
VIBRATION 10~500Hz, 2G 3AXES 10min. / 1cycle ( 1 HOUR / EACH AXES )
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:1.5KVAC  O/P-FG:0.5KVAC  1min.
ISOLATION RESISTANCE I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH  
STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH
DIMENSION 129*98*38mm
WEIGHT 0.45Kgs
SAFETY STANDARDS ----------
EMC STANDARDS ----------
NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC  70% RH. AMBIENT.
2.TOLERANCEĄGINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
7.C2,3,6 MUST BE REMOVED.