.LOW
COST, HIGH RELIABILITY |
.COMPACT
SIZE, LIGHT WEIGHT |
 |
.105¢J OUTPUT CAPACITOR |
.100%
FULL LOAD BURN-IN TEST |
.INTERNATIONAL
AC INPUT RANGE |
.BUILT
IN EMI FILTER, LOW RIPPLE NOISE |
.HIGH
EFFICIENCY, LOW WORKING TEMPERATURE |
.SOFT-START
CIRCUIT, LIMITING AC SURGE CURRENT |
.SHORT
CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED |
|
|
SM-S150-5 |
SM-S150-7.5 |
SM-S150-9 |
SM-S150-12 |
SM-S150-13.5 |
SM-S150-15 |
SM-S150-24 |
SM-S150-27 |
SM-S150-48 |
DC OUTPUT VOLTAGE |
5V |
7.5V |
9V |
12V |
13.5V |
15V |
24V |
27V |
48V |
OUTPUT V. TOLERANCE |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
OUTPUT RATED CURRENT |
30A |
20A |
16.7A |
12.5A |
11.2A |
10A |
6.5A |
5.6A |
3.2A |
OUTPUT CURRENT RANGE |
0-30A |
0-20A |
0-16.7A |
0-12.5A |
0-11.2A |
0-10A |
0-6.5A |
0-5.6A |
0-3.2A |
RIPPLE & NOISE
(p-p) |
150mV |
150mV |
180mV |
180mV |
180mV |
180mV |
240mV |
240mV |
240mV |
LINE REGULATION |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
LOAD REGULATION |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
DC OUTPUT POWER |
150W |
150W |
150.3W |
150W |
151.2W |
150W |
156W |
151.2W |
153.6W |
EFFICIENCY |
78% |
80% |
80% |
82% |
83% |
84% |
85% |
86% |
87% |
DC VOLTAGE ADJ. |
4.5-5.5V |
6-8.3V |
8-10.4V |
10.6-13.2V |
12-15V |
13.5-16.5V |
21-28V |
24-30V |
43-53V |
INPUT VOLTAGE RANGE |
88~132VAC / 176~264VAC SELECTED BY SWITCH 47~63Hz; 248~370VDC |
AC CURRENT |
3.2A/115V 1.6A/230V |
INRUSH CURRENT |
COLD START 35A |
LEAKAGE CURRENT |
<3.5mA/240VAC |
OVERLOAD PROTECTION |
105%~150% TYPE:OUTPUT SHUTDOWN RESET:RECYCLE AC
ON / OFF |
OVER VOLTAGE PROTECTION |
115%~135% |
125%~145% |
115%~135% |
OVER
TEMP. PROTECTION |
---------- |
TEMP. COEFFICIENT |
±0.03% / ¢J (0~50¢J)
|
SETUP, RISE, HOLD UP TIME |
100ms, 50ms, 20ms |
VIBRATION |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M£[ |
WORKING TEMP., HUMIDITY |
-10¢J~+60¢J(REFER
TO OUTPUT DERATING CURVE), 20%~90% RH |
STORAGE TEMP., HUMIDITY |
-20¢J~+85¢J,
10%~95% RH |
DIMENSION |
199*110*50mm |
WEIGHT |
0.8Kgs |
NOTE¡G |
1.ALL
PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25¢J 70% RH. AMBIENT. |
|
2.TOLERANCE¡GINCLUDE SET UP TOLERANCE,
LINE REGULATION, LOAD REGULATION. |
|
3.RIPPLE
& NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR
TERMINATED WITH A 0.1uF & 47uF CAPACITOR. |
|
4.LINE
REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. |
|
5.LOAD
REGULATION IS MEASURED FROM 0% TO 100% RATED LOAD. |
|
6.C2,3,11 MUST BE
REMOVED. |
|