30W Triple Output Switching Power Supply

.LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT
.105ºC  OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE .BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD PROTECTED
MODEL
SPECIFICATION
SM-30A SM-T30B
CH1 CH2 CH3 CH1 CH2 CH3
DC OUTPUT VOLTAGE 5V 12V -5V 5V 12V -12V
OUTPUT V. TOLERANCE ±2% +2,-6% +2,-10% ±2% +2,-6% ±6%
OUTPUT RATED CURRENT 3A 1A 0.5A 3A 1A 0.5A
OUTPUT CURRENT RANGE 0.5-3A 0.1-1A 0.1-0.5A 0.5-3A 0.1-1A 0.1-0.5A
RIPPLE & NOISE 50mVp-p 100mVp-p 50mVp-p 50mVp-p 100mVp-p 100mVp-p
LINE REGULATION ±0.5% ±1% ±1% ±0.5% ±1% ±1%
LOAD REGULATION ±0.5% ±5% ±5% ±0.5% ±5% ±5%
DC OUTPUT POWER 30W 33W
EFFICIENCY 70% 72%
DC VOLTAGE ADJ. CH1:+10,-5% CH1:+10,-5%
INPUT VOLTAGE RANGE 85~132VAC / 170~264VAC SELECTED BY SWITCH  47~63Hz;  240~370VDC
AC CURRENT 0.8A/115V  0.45A/230V
INRUSH CURRENT COLD START  18A/115V  36A/230V
LEAKAGE CURRENT <0.5mA/240VAC
OVERLOAD PROTECTION 105%~150%  TYPE:FOLDBACK CURRENT LIMITING  RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION ----------
OVER TEMP. PROTECTION ----------
TEMP. COEFFICIENT ±0.03% / ºC  (0~50ºC) ON +5V OUTPUT
SETUP, RISE, HOLD UP TIME 200ms, 100ms, 30ms
VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC  I/P-FG:1.5KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH 
STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH
DIMENSION 129*98*38mm
WEIGHT 0.4Kgs
SAFETY STANDARDS ----------
EMC STANDARDS ----------
NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC  70% RH. AMBIENT.
2.TOLERANCEĄGINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.