| .LOW
COST, HIGH RELIABILITY |
.COMPACT
SIZE, LIGHT WEIGHT |
 |
| .105ºC OUTPUT CAPACITOR |
.100%
FULL LOAD BURN-IN TEST |
| .INTERNATIONAL
AC INPUT RANGE |
|
| .HIGH
EFFICIENCY, LOW WORKING TEMPERATURE |
| .SOFT-START
CIRCUIT, LIMITING AC SURGE CURRENT |
| .SHORT
CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED |
|
|
|
SM-T40A |
SM-T40B |
SM-T40C |
| CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
| DC
OUTPUT VOLTAGE |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
| OUTPUT
V. TOLERANCE |
±2% |
±6% |
±8% |
±2% |
±6% |
±8% |
±2% |
±6% |
±6% |
| OUTPUT
RATED CURRENT |
3A |
2A |
0.5A |
3A |
2A |
0.5A |
3A |
1.5A |
0.5A |
| OUTPUT
CURRENT RANGE |
0.6-5A |
0.2-3A |
0.1-1A |
0.6-5A |
0.2-3A |
0.1-1A |
0.6-5A |
0.2-2A |
0.1-1A |
| RIPPLE
& NOISE |
100mVp-p |
120mVp-p |
100mVp-p |
100mVp-p |
120mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
120mVp-p |
| LINE
REGULATION |
±0.5% |
±1% |
±1% |
±0.5% |
±1% |
±1% |
±0.5% |
±1% |
±1% |
| LOAD
REGULATION |
±0.5% |
±4% |
±6% |
±0.5% |
±4% |
±6% |
±0.5% |
±4% |
±4% |
| RATED
OUTPUT POWER |
41.5W |
45W |
45W |
| EFFICIENCY |
72%
/ 115VAC |
72%
/ 115VAC |
72%
/ 115VAC |
| DC
VOLTAGE ADJ. |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
| INPUT
VOLTAGE RANGE |
85~264VAC
47~63Hz ; 120~370VDC |
| AC
CURRENT |
1.2A/115V 0.7A/230V |
| INRUSH
CURRENT |
COLD
START 20A/115V
40A/230V |
| LEAKAGE
CURRENT |
<3.5mA/240VAC |
| OVERLOAD
PROTECTION |
105%~150%/115VAC
TYPE:PULSING HICCUP SHUTDOWN
RESET:AUTO RECOVERY |
| OVER
VOLTAGE PROTECTION |
CH1:5.75~6.75V |
| TEMP.
COEFFICIENT |
±0.03%
/ ºC (0~50ºC) ON +5V OUTPUT |
| SETUP,RISE,HOLD
UP TIME |
1.6s,
50ms, 16ms / 115VAC 800ms,
50ms, 60ms / 230VAC |
| VIBRATION |
10~500Hz, 2G 3AXES 10min.
/ 1cycle ( 1 HOUR / EACH AXES ) |
| WITHSTAND
VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC
O/P-FG:0.5KVAC 1min. |
| ISOLATION
RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC
/ 100M Ohms |
| WORKING
TEMP., HUMIDITY |
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH |
| STORAGE
TEMP., HUMIDITY |
-20ºC~+85ºC, 10%~95% RH |
| DIMENSION |
129*98*38mm |
| WEIGHT |
0.45Kgs |
| SAFETY
STANDARDS |
---------- |
| EMC
STANDARDS |
---------- |
| NOTE
: |
1.ALL PARAMETERS
ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. |
|
2.TOLERANCEĄGINCLUDE SET UP TOLERANCE,
LINE REGULATION, LOAD REGULATION. |
|
3.RIPPLE & NOISE
ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED
WITH A 0.1uF & 47uF CAPACITOR. |
|
4.LINE REGULATION
IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. |
|
5.LOAD REGULATION IS MEASURED
FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. |
|
6.EACH OUTPUT PROVIDE
UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. |
|
7.C2,3,6 MUST BE REMOVED. |
|