.LOW COST, HIGH
RELIABILITY |
.COMPACT SIZE,
LIGHT WEIGHT |
 |
.105ºC OUTPUT CAPACITOR |
.100% FULL LOAD
BURN-IN TEST |
.INTERNATIONAL AC
INPUT RANGE |
.BUILT IN EMI
FILTER, LOW RIPPLE NOISE |
.HIGH
EFFICIENCY, LOW WORKING TEMPERATURE |
.SOFT-START
CIRCUIT, LIMITING AC SURGE CURRENT |
.SHORT
CIRCUIT, OVERLOAD PROTECTED |
|
|
SM-T50A |
SM-T50B |
SM-T50C |
SM-T50D |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
DC OUTPUT VOLTAGE |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
5V |
12V |
24V |
OUTPUT V. TOLERANCE |
±2% |
±5% |
±5% |
±2% |
±5% |
±5% |
±2% |
±5% |
±5% |
±2% |
±6% |
±6% |
OUTPUT RATED CURRENT |
7A |
1A |
1A |
5A |
1A |
1A |
4A |
1A |
1A |
3A |
1A |
1A |
OUTPUT CURRENT RANGE |
0.6-7A |
0.2-1A |
0.2-1A |
0.6-5A |
0.2-1A |
0.2-1A |
0.6-4A |
0.2-1A |
0.2-1A |
0.6-4A |
0.2-1.2A |
0.2-1.2A |
RIPPLE & NOISE (p-p) |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
50mV |
120mV |
120mV |
LINE
REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1% |
±1% |
LOAD REGULATION |
±1% |
±4% |
±4% |
±1% |
±4% |
±4% |
±1% |
±4% |
±4% |
±1% |
±5% |
±5% |
DC OUTPUT POWER |
52W |
49W |
50W |
51W |
EFFICIENCY |
66% |
69% |
71% |
72% |
DC VOLTAGE ADJ. |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
INPUT
VOLTAGE RANGE |
85~132VAC / 170~264VAC SELECTED BY SWITCH 47~63Hz; 240~370VDC |
AC
CURRENT |
1.6A/115V 0.8A/230V |
INRUSH
CURRENT |
COLD START 20A/115V 40A/230V |
LEAKAGE
CURRENT |
<0.5mA/240VAC |
OVERLOAD
PROTECTION |
105%~150% TYPE:FOLDBACK CURRENT LIMITING RESET:AUTO RECOVERY |
OVER
VOLTAGE PROTECTION |
---------- |
OVER
TEMP. PROTECTION |
---------- |
TEMP.
COEFFICIENT |
±0.03% / ºC (0~50ºC) ON +5V OUTPUT |
SETUP,
RISE, HOLD UP TIME |
200ms, 50ms, 16ms |
200ms,
80ms, 16ms |
VIBRATION |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES |
WITHSTAND
VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION
RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
WORKING
TEMP., HUMIDITY |
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH |
STORAGE
TEMP., HUMIDITY |
-20ºC~+85ºC, 10%~95% RH |
DIMENSION |
159*97*38mm |
WEIGHT |
0.54Kgs |
SAFETY
STANDARDS |
--------- |
EMC
STANDARDS |
---------- |
NOTE
: |
1.ALL PARAMETERS
ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC
70% RH. AMBIENT. |
|
2.TOLERANCE:INCLUDE SET UP TOLERANCE,
LINE REGULATION, LOAD REGULATION. |
|
3.RIPPLE & NOISE
ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED
WITH A 0.1uF & 47uF CAPACITOR. |
|
4.LINE REGULATION
IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. |
|
5.LOAD REGULATION IS MEASURED
FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. |
|
6.EACH OUTPUT PROVIDE UP TO MAXIMUM
CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. |
|