.LOW
COST, HIGH RELIABILITY |
.COMPACT
SIZE, LIGHT WEIGHT |
 |
.105ºC OUTPUT CAPACITOR |
.100%
FULL LOAD BURN-IN TEST |
.INTERNATIONAL
AC INPUT RANGE |
.BUILT
IN EMI FILTER, LOW RIPPLE NOISE |
.HIGH
EFFICIENCY, LOW WORKING TEMPERATURE |
.SOFT-START
CIRCUIT, LIMITING AC SURGE CURRENT |
.SHORT
CIRCUIT, OVERLOAD PROTECTED |
|
|
SM-S35-5 |
SM-S35-12 |
SM-S35-15 |
SM-S35-24 |
DC
OUTPUT VOLTAGE |
5V |
12V |
15V |
24V |
OUTPUT
V. TOLERANCE |
±2% |
±1% |
±1% |
±1% |
OUTPUT
RATED CURRENT |
7A |
3A |
2.4A |
1.5A |
OUTPUT
CURRENT RANGE |
0-7A |
0-3A |
0-2.4A |
0-1.5A |
RIPPLE
& NOISE |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
LINE
REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD
REGULATION |
±1% |
±0.5% |
±0.5% |
±0.5% |
DC
OUTPUT POWER |
35W |
36W |
36W |
36W |
EFFICIENCY |
70% |
76% |
78% |
78% |
DC
VOLTAGE ADJ. |
+10,-5% |
±10% |
±10% |
±10% |
INPUT
VOLTAGE RANGE |
85~132VAC
/ 170~264VAC
SELECTED BY SWITCH 47~63Hz;
240~370VDC |
AC
CURRENT |
0.8A/115V 0.45A/230V |
INRUSH
CURRENT |
COLD START 18A/115V 36A/230V |
LEAKAGE
CURRENT |
<0.5mA/240VAC |
OVERLOAD
PROTECTION |
105%~150% TYPE:FOLDBACK CURRENT
LIMITING RESET:AUTO RECOVERY |
OVER
VOLTAGE PROTECTION |
---------- |
OVER
TEMP. PROTECTION |
---------- |
TEMP.
COEFFICIENT |
±0.03% / ºC (0~50ºC) |
SETUP,
RISE, HOLD UP TIME |
200ms, 100ms, 30ms |
VIBRATION |
10~500Hz,
2G 10min./1cycle,
PERIOD FOR 60min. EACH AXES |
WITHSTAND
VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION
RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
WORKING
TEMP., HUMIDITY |
-10ºC~+60ºC(REFER
TO OUTPUT DERATING CURVE), 20%~90%
RH |
STORAGE
TEMP., HUMIDITY |
-20ºC~+85ºC, 10%~95% RH |
DIMENSION |
129*98*38mm |
WEIGHT |
0.4Kgs |
NOTE
: |
1.ALL PARAMETERS ARE SPECIFIED
AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. |
|
2.TOLERANCE¡GINCLUDE SET UP TOLERANCE,
LINE REGULATION, LOAD REGULATION. |
|
3.RIPPLE & NOISE ARE MEASURED
AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF
& 47uF CAPACITOR. |
|
4.LINE REGULATION IS MEASURED
FROM LOW LINE TO HIGH LINE AT RATED LOAD. |
|
5.LOAD REGULATION IS MEASURED
FROM 0% TO 100% RATED LOAD. |
|